Mon - Sat 8:00 AM - 6:00 PM
86-17369222201

FBCDZ Explosion-proof withdrawable counter-rotating axial flow ventilator fan

FBCDZ series main ventilator for mining or tunnel is a new type of high-efficiency, energy-saving, low-noise ventilator suitable for use as the main ventilator in coal mines. Combined with the ventilation network parameters of large and medium-sized coal mines, it is jointly designed and manufactured using curved and swept combined orthogonal technology.
The product has been certified by the national level, and it is believed that “this series of fans has the characteristics of high efficiency, low noise, compact structure, reliable performance, and convenient installation; the curved and swept combination orthogonal three-dimensional twisted blade technology used is the first in China;

Structures

1. Current collecto 2. Primary host group 3. Secondary host group  4. Diffusion tube 5. Diffusion tower

Diffusers and diffusion towers are generally lined with mufflers. According to the user’s requirements, it can be equipped with dampers (vertical gates or butterfly valves), special row mufflers, fan testing devices (testing air ducts, horizontal dampers or shutter valves, etc.), automatic walking devices, electronic control devices, online monitoring and control systems and wireless Personnel duty system, etc.

Advantages 1

The impeller stage adopts a counter-rotating type. Compared with ordinary two-stage axial flow fans, it has fewer front, middle and rear guide vanes, reducing the axial size and reducing losses at the same time. 

The main ventilator motor is installed in the flow isolation cavity of the main unit and dissipates heat through four ventilation ducts located in front and behind the motor.

Advantages 2

The flow channel is designed according to the principle of optimizing fan efficiency and has a beautiful appearance. The collector line is arc-shaped, and forms a tapered inlet flow channel with the hemispherical fairing, forming a uniform flow field in front of the impeller inlet to reduce flow loss; the diameter of the main unit inner cylinder is consistent with the impeller hub, and the flow channel is smooth No sudden changes; the diffuser adopts a tapered core cylinder, which can reduce aerodynamic noise while recovering dynamic pressure.

Advantages 3: blade

The main fan blades are made of cast aluminum alloy ZL104 and have been heat treated and inspected for flaw detection. The specific strength of aluminum alloy material is 3 times that of ordinary steel, ensuring that the main ventilator will not crack or break during normal operation; the blades adopt orthogonal bending and sweeping combined three-dimensional twisted blade technology, which increases the efficiency by 5%-10% , the noise is reduced by 10-20dB(A).

Technical specifications

NoRotating (r/min)Maximum efficiency point air volume Q ( m3/s )static pressure at maximum efficiency point P ( Pa,LP type)static pressure at maximum efficiency point P ( Pa,HP type)High-efficiency area air volume range Q
lower limit
(m3/s)
High-efficiency area air volume range Q
upper limit
(m3/s)
High-efficiency zone static pressure range P(LP type)
lower limit
(Pa)
High-efficiency zone static pressure range P(LP type)
upper limit
(Pa)
Efficient Zone Static Pressure Range P(HP type)
Lower limit
(Pa)
Efficient Zone Static Pressure Range P(HP type)
upper limit
(Pa)
Noise level than A sound level dB(A)
12145027249617409543264W38
131450342929225111553830W38
129801811401425122744914915241835W38
139802313381672153552717506152154W38
149802915521940184661220297132498W38
159803617812227235370223298192868W38
169804320272533276579926509313263W38
1798052228828603378902299210523684W38
18980612565320639921011225411794130W38
199807228583572461081127373713144601W38
209808431673958541261248414114555098W38
187404614631828307057719136722355W38
197405516302037358264221317492624W38
207406418062257419571223618302907W38
2174074199124884711178526039153205W38
22740852185273154127861285710043517W38
23740972388298562145941312310973844W38
2474011026003250701651025340011954186W38
2574012428213526791861112368912974542<38
2674014030513814892101203399014024913W38
27740157329141131002351297430315125298W38
28740175353944241112621395462816275698W38
2458086159719975512963020897342572W38
2558097173321666214668322667972790W38
26580110187523437016473924518623018W38
27580123202125277818479726439293255W38
28580137217427178720585728439993500W38
295801522332291597228919305010723755W38
3058016824963120107253984326411474018W38
31580186266533311182791051348512254290W38
32580204284035491303071119371313054572W38
33580224302037751433361190394913884862W38
34580245320640071563681264419214735161W38
35580267339742461704011339444215615469W38
36580291359444921854361417470016525786M38
37580316379647452014741497496417456112W38
38580342400450052185131579523618406447W38
39580370421852722355551663551519396790W38
40580399443755462545991749580220397143W38

Product On site

Mining ventilation fan on-site

Iquiry

en_USEnglish