Mining Flameproof 2x4kw Contra-rotating Axial Flow Local Fan
Mining Flameproof 2x4kw Contra-rotating Axial Flow Local Fan boasts a robust structure, exceptionally low noise operation, and impressive high wind pressure. It delivers superior efficiency and stable operation even in confined airflow areas, while maintaining a wide range of highly efficient operation. It can be operated as a whole unit or in single stages, providing the flexibility to optimize energy consumption and achieve significant energy savings. This makes it the ideal equipment for long-distance ventilation in mine roadways, ensuring efficient air circulation throughout the excavation process.
Structures
1. Current collector 2. Panel-type muffler front tube 3. First-level panel-type muffler host 4. First-level impeller 5. Second-level impeller
6. Secondary panel-type muffler main engine 7. Third-stage impeller 8. Guide vane tube 9. Panel-type muffler diffuser tube
Mining Flameproof 2x4kw Contra-rotating Axial Flow Local Fan incorporates a unique panel-type muffler structure for exceptional noise reduction. This design utilizes flexible materials throughout the flow channel, significantly dampening the high-frequency noise generated by the high-speed airflow. This results in a remarkably quiet operation compared to traditional fans. To ensure optimal performance, the outer diameters of the fan rectifier cap, muffler core, motor base, and rear muffler cone are meticulously designed to maintain a smooth flow channel within the fan body. This not only minimizes flow disruptions but also improves the fan’s pressure coefficient, leading to increased wind delivery distance. Furthermore, the panel-type muffler boasts a user-friendly design with a fixed end and removable muffler cotton. This allows for easy replacement in case of wear and tear, ensuring consistent noise reduction and extending the overall lifespan of the ventilator.
Parameters Table
No. | motor power | air Volume(m3/min) | full pressure(Pa) | Maximum full pressure efficiency(%) | compared to a sound levels[dB(A)] |
---|---|---|---|---|---|
No3.5 | 2×1.1 | 153~76 | 250~1500 | ≥75 | ≤30 |
No3.5 | 3×1.1 | 153~76 | 350~2100 | ≥75 | ≤30 |
No3.5 | 4×1.1 | 153~76 | 450~2700 | ≥75 | ≤30 |
No4 | 2×2.2 | 220~113 | 300~1800 | ≥75 | ≤30 |
No4 | 3×2.2 | 220~113 | 420~2520 | ≥75 | ≤30 |
No4 | 4×2.2 | 220~113 | 540~3240 | ≥75 | ≤30 |
No4.5 | 2×4 | 220~150 | 300~2300 | ≥75 | ≤30 |
No4.5 | 3×4 | 220~150 | 420~3220 | ≥75 | ≤30 |
No4.5 | 4×4 | 220~150 | 540~4140 | ≥75 | ≤30 |
No4.5 | 2×5.5 | 240~160 | 320~3100 | ≥75 | ≤30 |
No4.5 | 3×5.5 | 240~160 | 440~4340 | ≥75 | ≤30 |
No4.5 | 4×5.5 | 240~160 | 580~5580 | ≥75 | ≤30 |
No5.0 | 2×7.5 | 300~180 | 340~3500 | ≥75 | ≤30 |
No5.0 | 3×7.5 | 300~180 | 480~4900 | ≥75 | ≤30 |
No5.0 | 4×7.5 | 300~180 | 610~6300 | ≥75 | ≤30 |
No5.6 | 2×11 | 400~200 | 350~4000 | ≥80 | ≤25 |
No5.6 | 3×11 | 400~200 | 350~4000 | ≥80 | ≤25 |
No5.6 | 4×11 | 400~200 | 630~7200 | ≥80 | ≤25 |
No6.0 | 2×15 | 450~250 | 440~5100 | ≥80 | ≤25 |
No6.0 | 3×15 | 450~250 | 620~7100 | ≥80 | ≤25 |
No6.0 | 4×15 | 450~250 | 790~9200 | ≥80 | ≤25 |
No6.0 | 2×18.5 | 500~250 | 450~5500 | ≥80 | ≤25 |
No6.0 | 3×18.5 | 500~250 | 630~7700 | ≥80 | ≤25 |
No6.0 | 4×18.5 | 500~250 | 810~9900 | ≥80 | ≤25 |
No6.0 | 2×22 | 550~250 | 450~6000 | ≥80 | ≤25 |
No6.0 | 3×22 | 550~250 | 630~8400 | ≥80 | ≤25 |
No6.0 | 4×22 | 550~250 | 810~10800 | ≥80 | ≤25 |
No6.3 | 2×30 | 630~260 | 460~6300 | ≥80 | ≤25 |
No6.3 | 3×30 | 630~260 | 640~8820 | ≥80 | ≤25 |
No6.3 | 4×30 | 630~260 | 830~11340 | ≥80 | ≤25 |
No6.7 | 2×37 | 730~410 | 920~6500 | ≥80 | ≤25 |
No6.7 | 3×37 | 730~410 | 1200~9000 | ≥80 | ≤25 |
No6.7 | 4×37 | 730~410 | 1480~1160 | ≥80 | ≤25 |
No7.1 | 2×45 | 820~550 | 1480~6650 | ≥80 | ≤25 |
No7.1 | 3×45 | 820~550 | 1480~9130 | ≥80 | ≤25 |
No7.1 | 4×45 | 820~550 | 1850~11740 | ≥80 | ≤25 |
No7.5 | 2×55 | 980~630 | 1850~6800 | ≥80 | ≤25 |
No7.5 | 3×55 | 980~630 | 1850~9240 | ≥80 | ≤25 |
No7.5 | 4×55 | 980~630 | 2200~11880 | ≥80 | ≤25 |
No8.0 | 2×75 | 1250~680 | 2200~7100 | ≥80 | ≤25 |
Application
Underground Mines: This fan effectively tackles ventilation needs in various underground mining operations, including coal mines, metal mines, and non-metallic mines.
Tunnel Projects: The FBDY fan is perfectly suited for ventilation in diverse tunnel projects, encompassing highway tunnels, railway tunnels, and water conservancy tunnels.
Other Explosion-Prone Environments: Its flameproof design makes the FBDY fan ideal for ventilation in other settings with explosion risks, such as chemical plants, petrochemical plants, and power plants.
Advantages
Exceptional Aerodynamics: The FBCZ series utilizes advanced design principles to deliver exceptional aerodynamic performance. This translates to efficient airflow and optimized ventilation.
Enhanced Explosion Safety: The fan incorporates a built-in explosion-proof function within its inner cylinder, ensuring safe operation in potentially hazardous environments.
High Efficiency and Reduced Noise: The contra-rotating design, featuring two impellers spinning in opposite directions, minimizes aerodynamic losses and significantly improves efficiency compared to traditional fans. Additionally, the blades, engineered with a combination of orthogonal curved sweep and three-dimensional twisted blade technology, further contribute to a 5%-10% efficiency boost and a remarkable 10-20dB(A) noise reduction.
Intelligent advantages
We have integrated intelligent design into our underground axial flow fan ventilation systems, catering to the unique needs of both mining and tunneling projects. Our intelligent ventilation monitoring system boasts a comprehensive suite of features and cutting-edge technologies, enabling seamless optimization and enhanced safety across diverse underground environments.
Our intelligent ventilation monitoring system meticulously crafts customized ventilation plans for various mine zones, including coal working faces, excavation working faces, and development tunnels prone to disasters. Similarly, for tunnel engineering projects, our system ensures optimal airflow distribution throughout the tunnel, maintaining a safe and productive working environment.
Proactive monitoring and analysis of system performance ensure the stability and reliability of your ventilation system, minimizing downtime and safeguarding the safety of your operations, whether in mines or tunnels.
Granular control over airflow allocation reduces energy consumption, enhances worker comfort and productivity, and optimizes ventilation efficiency in both mining and tunneling operations.
Continuous monitoring of gas concentrations and detection of anomalies trigger timely alerts, enabling rapid intervention and averting potential disasters, preventing mine and tunnel accidents.
Product Cases
An iron ore mine customer in China has used our underground axial flow fan ventilation system. The air quality underground in mines has been greatly improved.
Customized axial fan ventilation system for a coal mine in China. Using FBDY series axial flow fans, the ventilation distance reaches 10km.
Axial fan ventilation system installed for a metal mining client in South America. The system effectively removes stale air, supplies fresh air, and controls dust, fumes, and other hazardous gases.
Client Support Services
Our commitment extends beyond providing high-performance fans. Our team of ventilation experts is readily available to assist you in selecting the right fan solution for your specific needs, providing expert advice and technical support throughout the entire process.